    HM-500 multi-gas leak detector
    Accurate and efficient
    The ultimate leak detection rate of 0.05g/a, the sniffer gun responds quickly in 1 second, accurately locks the leak point, and eliminates misjudgment and omission.
    One machine for multiple purposes
    Quadrupole mass spectrometry technology supports simultaneous detection of multiple refrigerants and can easily cope with complex process requirements.
    Stable and durable
    The core components have a long life, the maintenance cycle exceeds 1 year, and the RSD is less than or equal to 3.8% for 100 consecutive tests.
    Smart and easy to use
    One-click test design, simple and intuitive interface, convenient operation and easy to use.
    Product Overview

    The HM-500 multi-gas leak detector is designed for finished equipment already charged with refrigerant. It can accurately detect various refrigerants such as R134a and R600a, with a minimum leak detection rate as low as 0.05g/a. This product combines high sensitivity with excellent stability, and can be flexibly configured with other substances to be tested through custom settings, fully meeting the leak detection needs of home appliance manufacturing, automotive air conditioning, refrigeration equipment and other fields.

    Specifications
    Product SpecificationsTest HostPerformance ParametersR134a Minimum Detectable Leak Rate0.05g/a
    NameMulti-Gas Leak DetectorR600a Minimum Detectable Leak Rate0.05g/a
    ModelHM-500Detectable Mass Range2-100amu
    Dimensions724*370*1055mmCore SensorQuadrupole Mass Spectrometer
    Weight88kgIon Source2 Filaments, Dual Yttria-coated Iridium
    Power Voltage and Frequency220V/50HzMaximum Simultaneous Gas Detection4
    DisplayTouch Display ScreenStartup Ready Time<5min
    Sniffer Probe3m Sniffer Response Time<1s
    1. Cable Includes communication, samplingMeasurement Range0.05-999.99g/a
    2. Operation Handle Handle + Sniffer TipGas Flow at Sea Level and 1 Standard Atmosphere (1013 mbar)100-160ml/min (flow varies with altitude and atmospheric pressure)
    Note: Minimum detectable leak rate is calculated as 3.5 times the standard deviation of noise.